Food & Beverage Wastewater Treatment
Ultrafiltration (UF), Two-Step Reverse Osmosis™ (TSRO)
Client Overview
- Industry: Food & Beverage
- Year: 2019
- Daily Wastewater Production: 25,000 GPD
Challenge
Our client, a Food & Beverage company, faced significant challenges with their wastewater management:
Solution: Advanced Filtration System
We implemented a two-stage filtration system to address these challenges:
Project Approach
- Site Assessment:
- Collaborated with the company to understand their unique challenges
- Brainstormed tailored solutions
- Pilot Testing:
- Collected samples of raw wastewater
- Tested samples through UF and TSRO systems
Results
Detailed Analysis
Ultrafiltration (UF) Process Streams
Parameter | Unit | UF Feed | UF Permeate | UF Concentrate | % Removal by UF |
Total Solids | mg/L | 51,600 | 41,500 | 64,800 | 20% |
Chemical Oxygen Demand (COD) | mg/L | 53,100 | 41,200 | NA | 22% |
Total Kjeldahl Nitrogen (TKN) | mg/L | 1,370 | 1,110 | 1,960 | 19% |
Phosphorus | mg/L | 369 | 307 | 423 | 17% |
Conductivity | mS/cm | 10 | 9.04 | 9.52 | n/a |
pH | S.U. | 4.47 | 4.52 | 4.51 | n/a |
Two-Step Reverse Osmosis™ (TSRO) Process Streams
Parameter | Unit | UF Permeate | TSRO Permeate | TSRO Concentrate | % Removal by TSRO |
Total Solids | mg/L | 50,200 | 300 | 190,000 | 99% |
Chemical Oxygen Demand (COD) | mg/L | 41,200 | 20 | NA | >99.9% |
Total Kjeldahl Nitrogen (TKN) | mg/L | 1,330 | 18.9 | 2,270 | 99% |
Phosphorus | mg/L | 468 | 0.05 | 1,980 | >99.9% |
Conductivity | mS/cm | 11.5 | 0.837 | 29.3 | n/a |
pH | S.U. | 4.5 | 4.73 | 4.43 | n/a |
Key Benefits
- Clean Water Reclamation: Produced water suitable for direct discharge or reuse
- Cost Savings: Reduced wastewater disposal fees and eliminated surcharges
- Operational Efficiency: Streamlined wastewater management process
- Facility Expansion: Enabled production growth previously limited by wastewater constraints
- Value-Added Co-Products: Created concentrated streams suitable for animal feed or specialty products
- Job Creation: Facilitated company growth and new employment opportunities
- Environmental Compliance: Met stringent discharge requirements with high-quality treated water
Process Insights
- The UF system effectively removed suspended solids while allowing most dissolved solids to pass through.
- The TSRO system, combining Forward Osmosis and Reverse Osmosis, achieved exceptional removal rates:
- 99% reduction in total solids
- 99.9% reduction in Chemical Oxygen Demand (COD)
- Ammonia and phosphorus concentrations reduced to below detection limits
Are you facing a similar business challenge?
Call today and get discounted pilot testing when you mention this case study!